Air supply unit AVP
|
 |
Function of the product
Air supply unit AVP heats air using the heat of hot water (heat carrier) supplied from external heat supply sources and is designed for heating and transferring air in air handling plants, warm air curtains, return air plants for heating rooms of industrial and agricultural application.
The use of centrifugal fan allows using the unit in input systems of ventilation and gate air curtains
The unit is equipped with calorifer KSk, produced by our plant.
Air shall comply with maximum permissible content of deleterious substances according to GOST 12.1.005-88 with dust level not more than 0.5 mg/m3 and free of adhesive substances and fibrous materials.
The unit should be used in climatic regions with modrrate and cold climate (UHL) and allocation category 3 according to GOST 15150.
Heat carrier temperature is not more than 180°C and pressure not more than 1.2 MPa.
|
Specification of AVP
| Characteristic |
Model |
| AVP 60/3000 |
AVP 75/3000 |
AVP 100/5000 |
AVP 160/10000 |
AVP 200/16000 |
AVP 400/30000 |
Heat capacity,
kW ±8% |
59 |
76 |
97 |
164 |
194 |
398 |
| Air capacity, m3/h |
3000 |
3000 |
5000 |
10000 |
16000 |
30000 |
| Pressure built up by the unit, Pa |
810 |
810 |
810 |
1500 |
1050 |
1550 |
| Centrifugal fan |
VC14-46-3,15 1.5 kW 1410 rpm |
VC14-46-3,15 1.5 kW 1410 rpm |
VC14-46-3,15 2.2 kW 1410 rpm |
VC14-46-4 7.5 kW 1500 rpm |
VC14-46-6,3 7.5 kW 730 rpm |
VC14-46-8 22 kW 735 rpm |
| Calorifer |
Ksk 4-6 |
Ksk 4-7 |
Ksk 4-8 |
Ksk 4-9 |
2?KSk 4-8 |
Ksk 3-11 |
| Length, mm |
1132 |
1132 |
1170 |
1350 |
1780 |
2310 |
| Width, mm |
743 |
868 |
994 |
1000 |
1365 |
1830 |
| Height, mm |
714 |
704 |
720 |
865 |
1165 |
1760 |
| Net weight, kg, not more than |
95 |
105 |
175 |
235 |
400 |
840 |
Heat capacity is determined with the following parameters of heat-exchanging media:
inlet water temperature, 150 deg. C
outlet water temperature, 70 deg. C
inlet air temperature, 18 deg. C
|